Parameters for Procedure: Electrocardiogram (ECG) IMPC_ECG_001

Procedure carried out on Week 12

Version Type Req. Upload Req. Analysis Annotation Increment Option Ontology Options Derived Unit Data Type
Number of signals IMPC_ECG_001_001 1.2 simpleParameter Tick                                         FLOAT
HR IMPC_ECG_002_001 1.1 simpleParameter Tick         Tick                         bpm FLOAT
CV IMPC_ECG_003_001 1.0 simpleParameter                 Tick                         % FLOAT
RR IMPC_ECG_004_001 1.2 simpleParameter Tick         Tick                         ms FLOAT
PQ IMPC_ECG_005_001 1.0 simpleParameter                 Tick                         ms FLOAT
PR IMPC_ECG_006_001 1.1 simpleParameter Tick         Tick                         ms FLOAT
QRS IMPC_ECG_007_001 1.2 simpleParameter Tick         Tick                         ms FLOAT
ST IMPC_ECG_008_001 1.0 simpleParameter Tick         Tick                         ms FLOAT
QTc IMPC_ECG_009_001 1.0 simpleParameter                 Tick                         ms FLOAT
HRV IMPC_ECG_010_001 1.0 simpleParameter                 Tick                         bpm FLOAT
QTc Dispersion IMPC_ECG_011_001 1.0 simpleParameter                 Tick                         ms FLOAT
Mean SR amplitude IMPC_ECG_012_001 1.1 simpleParameter                                                 mV FLOAT
Mean R amplitude IMPC_ECG_013_001 1.1 simpleParameter                                                 mV FLOAT
rMSSD IMPC_ECG_014_001 1.0 simpleParameter                 Tick                         ms FLOAT
pNN5(6>ms) IMPC_ECG_015_001 1.2 simpleParameter                                                 % FLOAT
Equipment ID IMPC_ECG_016_001 1.0 procedureMetadata Tick                                         TEXT
Equipment Manufacturer IMPC_ECG_017_001 1.0 procedureMetadata Tick Tick                 Mouse Specifics, Inc.AD InstrumentsWorld Precision Instruments         TEXT
Equipment Model IMPC_ECG_018_001 1.0 procedureMetadata Tick Tick                 ECGenieML870/pML826/FE132Iso-DAM8AECGenie + gel pads         TEXT
Anesthetic IMPC_ECG_019_001 1.0 procedureMetadata Tick Tick                 IsofluraneAvertinTribromoethanolNo anesthesia         TEXT
Experimenter ID IMPC_ECG_020_001 1.0 procedureMetadata Tick                                         TEXT
Noise level IMPC_ECG_021_001 1.0 procedureMetadata                                                 TEXT
Light level IMPC_ECG_022_001 1.0 procedureMetadata                                                 TEXT
Date equipment last calibrated IMPC_ECG_023_001 1.1 procedureMetadata                                                 DATE
Analysis Software IMPC_ECG_024_001 1.0 procedureMetadata         Tick                 eMouseMatlab         TEXT